Products
iSR'obot Mona Lisa
 
 
 

iSR'obot Mona Lisa

 

The iSR’obot Mona Lisa potentially sets a new gold standard in prostate biopsy. Designed to provide surgeons with complete prostate coverage while accurately guiding the biopsy needle through only two skin punctures in the perineal region, thus reducing infections rate drastically.

The image-guided system enables the targeted location to be pin-pointed with an accuracy rate of ±1.0mm, enabling early detection of prostate cancer. The precise coordinates taken of each biopsy sample allow accurate repeat procedures to be carried out, thus facilitating patient surveillance and prostate cancer focal therapy.

  • Early accurate Prostate cancer detection through more accurate and systematic diagnosis
  • Using real time 3D ultrasound Robotic guided biopsy and maximal coverage of the prostate
  • Minimal risk of sepsis or haematuria
  • Ease of patient follow up: with patient data management, abilities to recall previous executed
  • biopsy plan, make remark on specific biopsy location and re-biopsy at exact location
  • Minimal invasive Focus Therapy enabled
  • User friendly intuitive interface monitoring and recording
 
Size and Weight
Overall Dimensions(Mounted Unit) (750 x 620 x 1460) mm, (Length x Width x Height)
Weight of iSR’obot Mona Lisa,
(robot included)
89.1 kg approx.
Size of robot (350 x 350 x 350) mm, (Length x Width x Height)
Weight of robot 4.7 kg approx.
   
Coverage
Transverse (70 x 70) mm, (Width x Height)
Angle (50 x 50) Degrees, (Horizontal x Vertical)
Accuracy +/- 1 mm
   
Electrical Information
Voltage 110 to 240VAC
Frequency 50/60Hz, Single Phase
Power consumption 250W
Operating Temperature +10°C to +40°C
Storage Temperature -10°C to +50°C
Relative humidity 30% to 70%
 
   
 

 

Minimally Invasive Procedure

  • Only 2 skin punctures at perineal area
  • Reduced risk of sepsis and haematuria
  • Improved accuracy in early diagnosis of cancer
  • Quicker post-operative recovery
  • Minimal post-operative discomfort

 


Accurate and reliable diagnosis

  • Cancer foci positions pinpointed within ±1.0mm

 


Short surgical time/target delivery

  • Prostate biopsy process only takes an average 15 minutes

 


Reproducible biopsy procedures


Maximal coverage of the prostate


User-friendly

  • Easy to setup and operate

 

Innovative virtual pivot point (or remote center of motion mechanism), ensures multiple needle entry through the same point.

Dual-cone concept enables complete prostate coverage

NonCate